Data cables

ftp4 utp4

Item
No:
Construction Conductor Pairs Shielding Packaging Length
S0101 UTP Cat5 24AWG 0.50 4 — — PB 305m
S0102 UTP Cat5 24AWG 7 x 0.20 4 — — PB 305m
S0103 UTP Cat5e 24AWG 0.50 4 — — PB 305m
S0104 UTP Cat5e 24AWG 7 x 0.20 4 — — PB 305m
S0105 UTP Cat5 24AWG 0.50 25 — — WR 305m
S0106 UTP Cat5e 24AWG 0.50 25 — — WR 305m
S0107 UTP Cat5 24AWG 0.53 4 Al Foil PB / WR 305m
S0108 UTP Cat5 24AWG 7 x 0.20 4 Al Foil PB / WR 305m
S0109 UTP Cat5e 24AWG 0.53 4 Al Foil PB / WR 305m
S0110 UTP Cat5e 24AWG 7 x 0.20 4 Al Foil PB / WR 305m
S0111 UTP Cat5 24AWG 0.53 4 Al Foil+Cu Brouding PB / WR 305m
S0112 UTP Cat5 24AWG 7 x 0.20 4 Al Foil+Cu Brouding PB / WR 305m
S0113 UTP Cat5e 24AWG 0.53 4 Al Foil+Cu Brouding PB / WR 305m
S0114 UTP Cat5e 24AWG 7 x 0.20 4 Al Foil+Cu Brouding PB / WR 305m
S0115 Water Prof Cat5 24AWG 0.50 4 Water Proof Materias WR 305m
S0116 Water Prof Cat5 24AWG 0.50 25 Water Proof Materias WR 305m
S0117 Water Prof Cat5 24AWG 0.50 4 Double Jacket WR 305m
S0118 Water Prof Cat5 24AWG 0.50 25 Double Jacket WR 305m

CAT5e-24AWG data cable – characteristics

Frequency
(MHz)
Impedance
ohms
RL
(Min.dB)
ATT
(Max,dB 100m)
NEXT
(Min. dB)
PS-NEXT
(Min. dB)
ACR
(Min. dB)
Propatation
Delay
(ns/100m)
Propatation
Delay Skew
(ns/100m)
PS-ACR
(Min. dB)
ELEFEXT
(Min. dB)
PS-ELFEXT
(Min. dB)
0.772 100+-15 20.00 1.8 67.0 64.0 70.2 0.65 20.0 68.2 66.0 63.0
1.0 20.00 2.0 65.3 62.3 68.2 66.3 63.8 60.8
4.0 23.00 4.1 56.3 53.3 57.2 55.2 51.7 48.7
8.0 24.50 5.8 51.8 48.8 51.0 49.0 45.7 42.7
10.0 25.00 6.5 50.3 47.3 48.8 47.0 43.8 40.8
16.0 25.00 8.2 47.3 44.3 43.0 42.1 39.7 36.7
20.0 25.00 9.3 45.8 42.8 41.5 39.5 37.7 34.7
25.0 24.30 10.4 44.3 41.3 38.9 36.9 35.8 32.8
31.25 23.30 11.7 42.9 39.9 36.5 34.2 33.9 30.9
62.5 20.70 17.0 38.4 35.4 26.4 24.4 27.8 24.9
100.0 19.00 22.0 35.3 32.3 18.3 16.3 23.8 20.8

QR 540 Coaxial Cables

u-1 pro-6

Construction Specification
 Standard 320 412 500 540
  (series) (series) (series) (series)
 Inner Conductor (mm) 1.80 2.26 2.78 3.15
Dielectric (mm) 7.45 9.30 11.50 13.03
Outer Conductor (mm) 8.12 10.50 12.70 13.72
Outer Sheath (mm) 10.03 12.50 14.70 15.30

Electrical Characteristics
 Impedance 75+/-2 ohms
 Nominal Capacitance 50 pF/m 15.2pF/ft
 Nominal Velocity of Propagation 88%
 Screen Efficiency at 5 Mhz 135Db min
 Dielectric Strength Dielectric 2.5Kv
Outer Shrath 5kV

Attenuation
Standard 320 series 412 series 500 series 540 series
f(MHz) Max. dB/100m Max. dB/100m Max.dB/100m Max. dB/100m
50 2.67 2.13 1.69 1.44
100 3.84 3.04 2.42 2.09
200 5.48 4.36 3.48 3.04
300 6.69 5.39 4.32 3.71
400 7.8 6.28 5.04 4.33
450 8.27 6.69 5.37 4.59
500 8.72 7.07 5.69 4.89
550 9.34 7.44 5.99 5.12
600 9.78 7.80 6.28 5.38
650 10.18 8.15 6.56 5.65
750 10.86 8.80 7.10 6.07
850 11.77 9.42 7.61 6.51
1000 12.76 10.30 8.34 7.12

RG7 Coaxial Cables

Physical Dimensions
 Component Standard Shield (Dia.mm) Tir-Shield (Dia.mm) Quad-Shield (Dia.mm)
 Inner Conductor 1.29 1.29 1.29
 Dielectric 5.72 5.72 5.72
 First Shield (Tape) 5.90 5.90 5.90
 Jacket 8.10 8.20 8.64
Steel Messenger Single 1.83 1.83 1.83
Dual 2.77 2.77 2.77

Mechanical Characteristics
 Minimum Breaking Strength of Messenger Dia. 1.83mm 166kgf
Dia. 2.77mm 818kgf

Electrical Characteristics
 Impedance 75
 Shielding Effectiveness (Ydb) 55MHz 68
300MHz 70
1000MHz 70
 SRL(Ydb) VHF 20
UHF 20

Attenuation (20 c, Udb/100m)
55MHz 4.1
211 MHz 7.7
270 MHz 8.8
300 MHz 9.1
330 MHz 9.8
400 MHz 10.8
450 MHz 11.5
550 MHz 12.8
750 MHz 15.2
870 MHz 16.5
1000 MHz 17.8

RG6 Coaxial Cables


Physical Dimensions
 Component Standard Shield (Dia.mm) Three-Shield (Dia.mm) Quad-Shield (Dia.mm)
 Inner Conductor 1.02 1.02 1.02
 Dielectric 4.57 4.57 4.57
 First Shield (Tape) 4.75 4.75 4.75
 Jacket 6.90 7.06 7.54
Steel Messenger Single 1.30 1.30 1.30
Dual 1.83 1.83 1.83

Mechanical Characteristics
 Minimum Breaking Strength of Messenger Dia. 1.30mm 82kgf
Dia. 1.83mm 166kgf

Electrical Characteristics
 Impedance 75
 Shielding Effectiveness (Ydb) 55MHz 68
300MHz 70
1000MHz 70
 SRL(Ydb) VHF 20
UHF 20

Attenuation (20 c, Udb/100m)
55MHz 5.3
211 MHz 10.0
270 MHz 11.0
300 MHz 11.6
330 MHz 12.3
400 MHz 13.6
450 MHz 14.4
550 MHz 16.2
750 MHz 19.0
870 MHz 20.6
1000 MHz 22.2

Coaxial Cable RG11

Physical Dimensions
 Component Standard Shield (Dia.mm) Tir-Shield (Dia.mm) Quad-Shield (Dia.mm)
 Inner Conductor 1.63 1.63 1.63
 Dielectric 7.11 7.11 7.11
 First Shield (Tape) 7.29 7.29 7.29
 Jacket 10.16 10.16 10.34
Steel Messenger Single 1.83 1.83 1.83
Dual 2.77 2.77 2.77

Mechanical Characteristics
 Minimum Breaking Strength of Messenger Dia. 1.83mm 166kgf
Dia. 2.77mm 818kgf

Electrical Characteristics
 Impedance 75
 Shielding Effectiveness (Ydb) 55MHz 68
300MHz 70
1000MHz 70
 SRL(Ydb) VHF 20
UHF 20

Attenuation (20 c, Udb/100m)
55MHz 3.2
211 MHz 6.2
270 MHz 7.1
300 MHz 7.3
330 MHz 7.9
400 MHz 8.8
450 MHz 9.4
550 MHz 10.4
750 MHz 12.4
870 MHz 13.5
1000 MHz 14.7